Delta ESR-48/56CN Telecom Power Rectifier Module (48V 56A 3200W High-Temperature Resistant) - Isometric 45-Degree Angled View
DeltaModel: ESR-48/56CN

Delta ESR-48/56CN Telecom Power Rectifier Module (48V 56A 3200W High-Temperature Resistant)

The Delta ESR-48/56CN is a heavy-duty telecom rectifier module engineered for high-temperature and harsh outdoor cellular base stations, delivering -48V 56A (3200W) with rugged thermal management and >96% peak conversion efficiency.

Talk to RICEWIND

Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.

Clear support from selection to delivery

360°Technical support
N+Service commitment
3Steps shipping
100%Customer satisfaction
Rated DC Output Current
-48VDC (-42V ~ -58V)
Rated Output VA / Wattage
3200W High Power Density
Peak Energy Efficiency
96.0%
Nominal DC Output Voltage
-48VDC (-42V ~ -58V)
AC Input Voltage
85V - 300V AC Wide Grid Tolerance
Operating Temperature Range
-40°C ~ +75°C

What this product is

What this product is

The Delta ESR-48/56CN is a heavy-duty telecom rectifier module engineered for high-temperature and harsh outdoor cellular base stations, delivering -48V 56A (3200W) with rugged thermal management and >96% peak conversion efficiency.

What problem it solves

Resolves severe power grid instability, excessive OPEX energy dissipation, battery degradation, and cabinet thermal constraints.

Who and where it is for

5G cellular cell sites, core telecom DC plants, data center critical power infrastructure, railway signaling, and industrial UPS.

Core advantages

  • Enhanced Thermal Resilience: Optimized heat dissipation engineered for extreme desert outdoor enclosures up to +75°C.
  • 56A High-Power Output: 3200W single-unit delivery reliably powers high-drain 5G AAU radios and multi-carrier BBUs.
  • Live Hot-Swap Agility: Safe tool-free insertion/extraction under live DC bus with autonomous digital current sharing <3%.
  • Robust Grid Immunity: Integrated 4kV surge suppressors and wide-band EMI filters guard against lightning transients.

Technical specifications

Key specificationsValue
Rated DC Output Current-48VDC (-42V ~ -58V)
Rated Output VA / Wattage3200W High Power Density
AC Input Voltage85V - 300V AC Wide Grid Tolerance
Operating Temperature Range-40°C ~ +75°C
Nominal DC Output Voltage-48VDC (-42V ~ -58V)
Peak Energy Efficiency96.0%
Overall System EfficiencyUp to 96.2% (Gold Standard)
Acoustic Noise≤ 55 dBA (at 25°C ambient load)
Ingress Protection RatingIP20 (Indoor Dust & Finger Proof)
Dielectric Withstand Voltage3000VAC Input to Ground (< 5mA)

Applications

01

Telecom 4G/5G macro cellular base stations and distributed remote power sites

02

Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups

03

Utility power grid dispatch centers and high-voltage substation DC switchgear rooms

04

Railway transit signaling, automated train control, and communications equipment rooms

Frequently asked questions

Continue exploring