ZTE / Remote Radio Units (RRU)

ZXSDR R882A S8500 Equipment information & support

The ZTE ZXSDR R882A S8500 is a dual-channel high-power outdoor remote radio unit supporting multi-carrier aggregation and high-linearity amplification, housed in a sealed IP65 chassis for cellular towers.

Equipment information

Brand
ZTE
Equipment model
ZXSDR R882A S8500
Equipment type
Remote Radio Units (RRU)
Controller / software version
Confirm against the installed equipment
View full product specifications
ZTE ZXSDR R882A S8500 Remote Radio Unit (Multi-Carrier Outdoor Distributed Radio Unit) - Official Front View

Information below comes from the current product catalogue. Confirm the controller, software version and configuration of the installed equipment separately.

Radio Frequency Architecture
Dual-Channel High-Power Transceiver
DC Operating Voltage Specification
48V DC (-37V ~ -57V Wide Range)
Baseband Optical Interface
Dual High-Speed CPRI Optical Ports
Ingress Protection Rating
IP65 (Full Outdoor Weatherproof)
Thermal Cooling Architecture
High-Conductivity Aluminum Passive
Mounting System Hardware
Pipe Pole Clamps & Bracket

Alarms & troubleshooting

AC_IN_FAIL / MAINS_LOST
Input Amber / Alarm Red solid
Utility grid failure, AC breaker tripped, or line voltage out of range
1. Measure incoming AC voltage with a multimeter; 2. Check input circuit breaker and upstream distribution; 3. System automatically soft-starts upon power restoration.
DC_OV_SHUTDOWN / LOCKOUT
Alarm Red solid, module output locked out
DC bus overvoltage or internal feedback sensor fault
1. Measure actual DC bus terminal voltage; 2. Cycle AC supply breaker to discharge capacitors and reboot; 3. Replace power module if fault recurs persistently.
FAN_FAIL / OVER_TEMP
Temp Yellow solid, fan halted or derated
Air intake dust blockage or fan bearing obstruction
1. Clean dust accumulation from intake grilles and filters; 2. Verify ambient room air conditioning is operational; 3. Replace cooling fan if rotation remains stalled.

Access Complete Maintenance & Full Alarm Troubleshooting Manual

This page lists high-frequency critical alarm codes commonly encountered in field maintenance. Comprehensive manufacturer troubleshooting matrices, board-level repair guides, detailed electrical schematics, and firmware commissioning manuals are delivered alongside equipment upon formal project procurement, accompanied by dedicated FAE technical support.

Share on-site information

  1. 01

    Identify the exact model

    Record the nameplate, system model and controller or module model.

  2. 02

    Keep the alarm details

    Record the full alarm text, indicator colour, timing and whether it persists.

  3. 03

    Describe recent changes

    Note recent replacements, software updates or configuration changes.

Record information visible in the existing interface. Electrical measurements, disassembly and replacement should follow the applicable manufacturer's manual and be performed by qualified personnel.

Your model and these details will be added to the enquiry form for you to review before sending.

Related technical articles

Browse the technical guides or send a question about this model.

View all articles

Need a replacement module or supporting equipment?

Confirm the full model, system configuration and compatibility requirements before enquiring about suitable products.

Ask about suitable products

Have a model and an on-site issue?

Share the exact model, alarm text and observed symptoms to help identify relevant information and compatibility requirements.

Request technical support