AC Input Voltage
100VAC ~ 288VAC single-phase VAC
DC Output Voltage
220VDC (176V ~ 286V) V AC
Physical Dimensions
85 (2U) × 430 × 500 mm
Form Factor & Mounting
19-Inch Rackmount
Output Power Factor PF
1.0 (Rated 6kVA / 6kW)
Power Conversion Efficiency
≥ 96.0%

What this product is

What this product is

Telecom-grade power infrastructure module designed for VERTIV power architecture.

What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

Core advantages

  • Unity Power Factor 1.0: 6kVA/6kW high power density matching modern high-load IT and telecom demands
  • Ultra-Wide Input Voltage (100V-288V): Resilient against harsh grid fluctuations to minimize battery wear
  • High-Efficiency Online Double Conversion: Up to 95.5% efficiency for maximized energy savings and power purity
  • Flexible Rack/Tower Convertible Design: Ultra-compact 2U form factor for standard cabinets and edge sites

Technical specifications

Key specificationsValue
AC Input Voltage100VAC ~ 288VAC single-phase VAC
DC Output Voltage220VDC (176V ~ 286V) V AC
Output Power Factor PF1.0 (Rated 6kVA / 6kW)
Power Conversion Efficiency≥ 96.0%
Monthly Self-Discharge Rate< 2% per month (at 20°C standard)
Physical Dimensions85 (2U) × 430 × 500 mm
Designed Float Service Life10 to 12 Years (at 25°C nominal)
Case Flame RetardancyReinforced ABS Enclosure (UL94-V0)
Terminal Tightening Torque10 to 12 N·m (M8 Silver-Plated Copper)
Form Factor & Mounting19-Inch Rackmount

Applications

01

Telecom cellular base stations and central offices -48V DC backup battery strings

02

Data center high-rate UPS battery banks delivering critical runtime for server loads

03

Electric utility substations 110V/220V DC switchgear breaker trip and closing power

04

Off-grid renewable solar/wind hybrid storage and industrial uninterruptible backup sites