Vertiv Liebert ITA2 6kVA/6kW Industrial Rack/Tower Online Double-Conversion UPS Official Studio Photo 1
VertivModel: Liebert ITA2 6kVA UPS

Vertiv Liebert ITA2 (6kVA/6kW Industrial Rack/Tower Online Double-Conversion UPS)

The Vertiv Liebert ITA2 6kVA is an industrial-grade, high-frequency online double-conversion UPS featuring a unity power factor (PF=1.0, 6kW capacity), a 2U rack/tower convertible form factor, and ultra-wide utility grid adaptability, engineered to deliver continuous, zero-transfer clean AC power to mission-critical telecom and industrial nodes.

Talk to RICEWIND

Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.

Clear support from selection to delivery

360°Technical support
N+Service commitment
3Steps shipping
100%Customer satisfaction
Rated Output Power
6kVA / 6kW (Output Power Factor 1.0)
Topology
Online Double-Conversion
Form Factor
19-Inch Rackmount
AC Input Voltage
176V AC ~ 288V AC (Ultra-Wide AC Grid Tolerance)
Power Conversion Efficiency
≥ 95.5%
Battery System Voltage
±96V / ±120V / ±144V / ±192V DC Flexible Config

What this product is

What this product is

A 2U DSP-controlled high-frequency double-conversion online uninterruptible power supply, equipped with IGBT rectification, flexible DC link topology, and convertible mounting mechanics for standard 19-inch racks or standalone towers.

What problem it solves

Eliminates grid power anomalies including sags, surges, harmonics, and blackout risks, while resolving footprint constraints, rigid battery configuration limits, and severe thermal derating in harsh industrial installations.

Who and where it is for

Edge computing micro-datacenters, industrial SCADA/PLC control automation, telecom BBU/RRU distribution shelters, healthcare imaging gear, and rail transit signaling rooms.

Core advantages

  • Unity Power Factor (PF=1.0): 6kVA delivers a full 6kW active power capacity, optimizing cabinet rack payload
  • Ultra-wide input window (176V to 288V AC) slashes unnecessary battery cycle counts to preserve battery service life
  • Multi-tap DC bus accommodates 16/20/24/32 battery blocks (±96V to ±192V DC), cutting replacement CAPEX
  • Native 3+1 parallel multi-chassis scalability supports dynamic N+X redundancy and power expansion

Technical specifications

Key specificationsValue
Rated Output Power6kVA / 6kW (Output Power Factor 1.0)
AC Input Voltage176V AC ~ 288V AC (Ultra-Wide AC Grid Tolerance)
Power Conversion Efficiency≥ 95.5%
TopologyOnline Double-Conversion
Parallel Redundancy CapacitySupports Up to 3+1 Parallel Redundancy
Battery System Voltage±96V / ±120V / ±144V / ±192V DC Flexible Config
Form Factor19-Inch Rackmount
Operating Temperature Range0°C ~ +50°C (Robust Operating Range)

Applications

01

Edge telecom hubs, optical transmission nodes, and remote microwave basestations

02

Industrial manufacturing SCADA, DCS distribution racks, and assembly line controllers

03

Hospital MRI/CT auxiliary power, laboratory analyzers, and medical clean systems

04

Data center edge nodes and distributed enterprise networking distribution frames